AIROSOL COMPANY, INC.
MCKAY CHEMICALS MECHANICS BRAND
MATERIAL
SAFETY DATA SHEET
|
PRODUCT NAME: |
GAS POWER BOOSTER |
Hmis Codes: |
H |
F |
R |
P |
|
PRODUCT CODE: |
50116 |
|
2 |
3 |
0 |
B |
|
SECTION I - MANUFACTURER
IDENTIFICATION |
|
MANUFACTURER’S NAME: |
Airosol Company, Inc. |
|
ADDRESS: |
|
|
EMERGENCY PHONE: |
1-800-535-5053 |
|
INFORMATION PHONE: |
1-800-633-9576 |
|
DATE REVISED: |
|
|
SECTION I I- HAZARDOUS
INGREDIENTS/SARA III INFORMATION |
OCCUPATIONAL
EXPOSURE LIMITS
|
HAZARDOUS COMPONENTS |
CAS NUMBER |
TWA/PEL |
ACGIH/TLV |
% |
|
Methyl Alcohol |
67-56-1 |
200
ppm |
200
ppm |
65-70 |
|
Isopropyl Alcohol |
67-63-0 |
400
ppm |
400
ppm |
25-30 |
|
Xylene |
1330-20-7 |
100
ppm |
100
ppm |
>1 |
|
SECTION III- PHYSICAL/CHEMICAL
CHARACTERISTICS |
|
BOILING POINT: |
N/D |
SPECIFIC GRAVITY: |
0.788 @ 77°F |
|
VAPOR DENSITY: |
1.105 (Air = 1) |
EVAPORATION RATE: |
(n-Butyl
Acetate=1) Faster Than |
|
APPEARANCE AND ODOR: |
Yellow liquid, alcohol odor |
SOLUBILITY IN WATER: |
Soluble |
|
SECTION IV- FIRE AND EXPLOSION
HAZARD DATA |
|
FLASH POINT: |
N/D |
METHOD USED: |
PMCC |
|
||||
|
FLAMMABLE LIMITS IN AIR BY VOLUME: |
LOWER: |
6.0 % |
UPPER: |
36.0 % |
|
|||
|
EXTINGUISHING MEDIA: Water spray, dry chemical or alcohol foam. |
||||||||
|
SPECIAL FIREFIGHTING PROCEDURES: |
Wear self-contained breathing
apparatus and full protective clothing. |
|||||||
|
UNUSUAL FIRE AND EXPLOSION
HAZARDS: Methanol burns with a clean
clear flame which is almost invisible in daylight. Stay upwind. |
||||||||
|
SECTION V- REACTIVITY DATA |
|
STABILITY: Stable.
Avoid heat, sparks, flames. |
|
CONDITIONS TO AVOID: Presence of incompatible materials and
ignition sources. |
|
INCOMPATIBILITY (MATERIALS TO
AVOID): Strong oxidizers, strong
bases, strong dehydrating agents. May
be corrosive to lead and aluminum. |
Page
1 of 3
|
PRODUCT
NAME: |
GAS
POWER BOOSTER |
|
PRODUCT
CODE: |
50116 |
|
SECTION V- REACTIVITY DATA
(continued) |
|
HAZARDOUS DECOMPOSITION OR
BYPRODUCTS: Formaldehyde, carbon
monoxide, smoke, and oxides of nitrogen. |
|
HAZARDOUS POLYMERIZATION: Not expected to occur. |
|
SECTION VI- HEALTH HAZARD DATA |
|
INHALATION HEALTH RISKS AND SYMPTOMS
OF EXPOSURE: Prolonged overexposure
may cause coughing, shortness of breath, dizziness and intoxication. |
NATURE
OF HAZARD:
|
EYES: |
High vapor concentration or liquid
contact causes irritation, tearing and burning. |
|
|
INGESTION: Swallowing even small amounts of methanol
can cause blindness and death, other effects may be
nausea, headache, abdominal pain, vomiting and visual disturbances ranging
from blurred vision to light sensitivity. |
|
|
|
CARCINOGENICITY: |
NTP? |
IARC? |
OSHA REGULATED? |
|
Presently not on any list |
|||
|
MEDICAL CONDITIONS GENERALLY
AGGRAVATED BY EXPOSURE: NA |
|
EMERGENCY
AND FIRST AID PROCEDURES: |
|
|
|
INHALATION: Remove patient to fresh air. Get medical attention immediately. |
INGESTION: Do not induce vomiting. Get medical attention immediately.
|
SKIN
AND EYE CONTACT: |
|
EYES:
Immediately flush eyes with large amounts of water for at least 15
minutes. Hold eyelids apart to ensure
complete flushing. Do not attempt to
neutralize with chemical agents. Get
medical help immediately. |
|
SKIN:
Remove contaminated clothing and wash under shower for 15 minutes
using soap. Seek medical attention if
irritation occurs. |
|
SECTION VII- PRECAUTIONS FOR
SAFE HANDLING AND USE |
|
STEPS TO BE TAKEN IN CASE LARGE AMOUNT
OF MATERIAL IS RELEASED OR SPILLED:
Remove all sources of ignition, avoid breathing vapors and remove with
inert absorbent. Dispose of as
hazardous waste. |
|
WASTE DISPOSAL METHOD: Dispose of in accordance with federal,
state, and local regulations regarding pollution. |
|
PRECAUTIONS TO BE TAKEN IN HANDLING
AND STORING: Keep away from heat,
sparks, or open flame. |
|
SECTION VIII- CONTROL MEASURES |
|
RESPIRATORY PROTECTION: Usually not required if it is used as it is
described on the label. |
|
VENTILATION: Provide adequate ventilation to keep mist
or vapors below allowable exposure levels. |
|
PROTECTIVE GLOVES: For prolonged or repeated contact, wear
gloves made of butyl or nitrile. |
|
EYE PROTECTION: Recommend safety glasses with unperforated
sideshields. |
|
OTHER PROTECTIVE CLOTHING OR
EQUIPMENT: Long sleeves and long
pants. |
Page
2 of 3
|
PRODUCT
NAME: |
GAS
POWER BOOSTER |
|
PRODUCT
CODE: |
50116 |
|
SECTION VIII- CONTROL MEASURES
(continued) |
|
WORK/HYGIENIC PRACTICES: |
|
SECTION IX- REGULATORY
INFORMATION |
SUPERFUND
AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA) TITLE III:
CHEMICAL CAS NUMBER CONCENTRATION
%
Methanol 67-56-1 65-70
Xylene 1130-20-7 <1
FEDERAL
EPA: Comprehensive Environmental
Response, Compensation and Liability act of 1980 (CERCLA) requires the
notification of the
CHEMICAL CAS NUMBER CONCENTRATION
% UPPER BOUND RQs IN #S
Xylene 1330-20-7 <1 100
Methanol 67-56-1 65-70
IPA 67-63-0 25-30
Xylene 1330-20-7 <1
Methanol 67-56-1 65-70
IPA 67-63-0 25-30
Xylene 1330-20-7 <1
NEW
Methanol 67-56-1 65-70
IPA 67-63-0 25-30
Xylene 1330-20-7 <1
RHODE
Methanol 67-56-1 65-70
IPA 67-63-0 25-30
Xylene 1330-20-7 <1
TOXIC
SUBSTANCES CONTROL ACT (TSCA) STATUS:
NFPA
RATING AS AN AEROSOL: N/A
HMIS: HEALTH 2
REACTIVITY 0 FLAMMABILITY 3
CARCINOGENICITY: CHEMICAL IARC NTP OSHA
None
listed
NOTE:
THE INFORMATION IN THIS
DOCUMENT IS BELIEVED TO BE CORRECT AS OF THE DATE ISSUED. HOWEVER, NO WARRANTY OF MERCHANTABILITY,
FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY OTHER WARRANTY IS EXPRESSED OR TO BE
IMPLIED REGARDING THE ACCURACY OR COMPLETENESS OF THIS INFORMATION OR THE
PRODUCT,THE SAFETY OF THIS PRODUCT, OR THE HAZARDS
RELATED TO ITS USE. THIS INFORMATION AND
PRODUCT ARE FURNISHED "AS IS" AND ON THE CONDITION THAT THE PERSON
RECEIVING THEM SHALL MAKE THEIR OWN DETERMINATION AS TO THE SUITABILITY OF THE
PRODUCT FOR THEIR PARTICULAR PURPOSE AND ON THE CONDITION THEY ASSUME THE RISK
OF THEIR USE THEREOF.
Page
3 of 3